Technical Specifications
-
SPSRxxx401E1-64/100
-
SPSRxxx231E1-64/100
-
SPSRxxx401S1-64/100
-
SPSRxxx231S1-64/100
-
SPSRxxx401E1-64/100
-
Rated voltage(Vac):
400
-
Input voltage(Vac):
85~265
-
Power consumption(VA):
per phase<1
-
External transformer:
3CT 100A/40mA(5m)
-
Input current(A):
64/100
-
Start current:
4‰(1 level)
-
Energy positive:
EPI / EPE
-
Electrical measurement:
Voltage/Current/Power factor/Frequency/Active power/Reactive power/Apparent power
-
Active energy accuracy:
AP Class1(IEC62053-22)
-
RP Class1(IEC62053-23)
-
Wireless:
2.4GWi-Fi / 4G
-
Internal communication:
LoRa
-
Interface:
RS485 / CAN
-
Media:
UTP
-
Protocol:
MODBUS-RTU
-
Display:
4*LED, Button
-
Dimensions(L*W*H)(mm):
206*96*56
-
Weight (kg):
0.15
-
Ingress Protection:
IP20
-
Installation:
35mm DIN Rail
-
Operating Temperature(℃):
-25~+50
-
-
SPSRxxx231E1-64/100
-
Rated voltage(Vac):
230
-
Input voltage(Vac):
85~265
-
Power consumption(VA):
per phase<1
-
External transformer:
1CT 100A/40mA(5m)
-
Input current(A):
64/100
-
Start current:
4‰(1 level)
-
Energy positive:
EPI / EPE
-
Electrical measurement:
Voltage/Current/Power factor/Frequency/Active power/Reactive power/Apparent power
-
Active energy accuracy:
AP Class1(IEC62053-22)
-
RP Class1(IEC62053-23)
-
Wireless:
2.4GWi-Fi / 4G
-
Internal communication:
LoRa
-
Interface:
RS485 / CAN
-
Media:
UTP
-
Protocol:
MODBUS-RTU
-
Display:
4*LED, Button
-
Dimensions(L*W*H)(mm):
206*96*56
-
Weight (kg):
0.15
-
Ingress Protection:
IP20
-
Installation:
35mm DIN Rail
-
Operating Temperature(℃):
-25~+50
-
-
SPSRxxx401S1-64/100
-
Rated voltage(Vac):
400
-
Input voltage(Vac):
85~265
-
Power consumption(VA):
per phase<1
-
External transformer:
3CT 100A/40mA(5m)
-
Input current(A):
64/100
-
Start current:
4‰(1 level)
-
Energy positive:
EPI / EPE
-
Electrical measurement:
Voltage/Current/Power factor/Frequency/Active power/Reactive power/Apparent power
-
Active energy accuracy:
AP Class1(IEC62053-22)
-
RP Class1(IEC62053-23)
-
Wireless:
2.4GWi-Fi / 4G
-
Internal communication:
LoRa
-
Interface:
RS485 / CAN
-
Media:
UTP
-
Protocol:
MODBUS-RTU
-
Display:
4LED, 4Button, LCD
-
Dimensions(L*W*H)(mm):
206*96*56
-
Weight (kg):
0.15
-
Ingress Protection:
IP20
-
Installation:
35mm DIN Rail
-
Operating Temperature(℃):
-25~+50
-
-
SPSRxxx231S1-64/100
-
Rated voltage(Vac):
230
-
Input voltage(Vac):
85~265
-
Power consumption(VA):
per phase<1
-
External transformer:
1CT 100A/40mA(5m)
-
Input current(A):
64/100
-
Start current:
4‰(1 level)
-
Energy positive:
EPI / EPE
-
Electrical measurement:
Voltage/Current/Power factor/Frequency/Active power/Reactive power/Apparent power
-
Active energy accuracy:
AP Class1(IEC62053-22)
-
RP Class1(IEC62053-23)
-
Wireless:
2.4GWi-Fi / 4G
-
Internal communication:
LoRa
-
Interface:
RS485 / CAN
-
Media:
UTP
-
Protocol:
MODBUS-RTU
-
Display:
4LED, 4Button, LCD
-
Dimensions(L*W*H)(mm):
206*96*56
-
Weight (kg):
0.15
-
Ingress Protection:
IP20
-
Installation:
35mm DIN Rail
-
Operating Temperature(℃):
-25~+50
-
FAQ
-
Qno title